IPC6521-Z20-FI 1080P Intelligent Network Speed
Dome
User Guide
5 Device Configuration
Issue 02 (2013-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
77
Table 5-23
Parameter description
Parameter
Description
Setting
Alarm
input
Device ID
ID of the alarm input device.
-
Enable
Indicates whether to enable
the alarm input function.
Name
User-defined device name.
Type
Select
Normal open
or
Normal close
according to
the device status.
Alarm check
interval
Interval for checking alarms.
[Default value]
60
[Unit]
s
Alarm
output
Device ID
ID of the alarm output
device.
-
/
Manual control of the output
device status.
NOTE
This function cannot be used
with the alarm linkage function.
If the function is used with the
alarm linkage function, the
alarm linkage actions will be
affected.
Name
User-defined device name.
Duration
Duration of the alarm.
[Default value]
10
[Unit]
s
NOTE
If
Duration
is set to
0
, the
alarm persists permanently.
Step 3
Click
Save
.
----End
5.6.2 Configuring Temperature Alarm Parameters
When the device operating temperature is out of a specific range (-30°C to +85°C), a
temperature alarm is generated.
Step 1
Choose
Settings
>
Alarm Configuration
>
Temperature Alarm
.