IPC6521-Z20-FI 1080P Intelligent Network Speed
Dome
User Guide
5 Device Configuration
Issue 02 (2013-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
59
If the object is not marked on the live video image, removed object detection is not
properly configured or not enabled.
Table 5-16
lists the possible causes and their
solutions.
Table 5-16
Possible causes
Cause
Solution
The surveillance area is too large.
Adjust the focal length and dimensions of
the surveillance area to ensure that the
intended object can be detected.
The surveillance area is too small.
The behavior analysis function is disabled.
Enable the behavior analysis function.
The sensitive area is not in
Enable
state
when
Behavior type
is set to
Removed
object detection
on the
Behavior Analysis
Parameters
page.
Select the sensitive area ID from the
sensitive area list and click
Enable/Disabled
to enable the sensitive
area.
Video alarm deployment
is not selected on
the
Alarm Deployment Policy
page that is
displayed when you choose
Settings
>
Alarm Configuration
>
Alarm
Deployment Policy
.
Select
Video alarm deployment
.
5.3.7 Configuring the Tripwire Detection Function
The tripwire detection function checks whether a person or an object crosses a specified
tripwire in a specified direction. The system generates an alarm when a person or an object
crosses the tripwire.
Prerequisite
Enable the behavior analysis function. For details, see
5.3.1 Enabling Behavior Analysis
Switch
.
After clicking a domain or a link to jump to a required page, you can press
Alt+←
(left arrow key) to
return to the previous page.
Procedure
Step 1
Log in to the eSpace IP camera (IPC) web page as the system administrator.
Step 2
Choose
Settings
>
Intelligent Analysis
>
Behavior Analysis Parameters
.
The
Behavior Analysis Parameters
page is displayed.
Step 3
Set
Behavior type
to
Tripwire detection
, as shown in
Figure 5-15
.