3 Commissioning Process
Airbridge BTS3606E&3606AE
System Commissioning Guide
3-16
Huawei Technologies Proprietary
Issue 02 (2006-10-10)
z
The loading of the BTS software does not affect the service.
z
The service is affected if you activate the BTS software.
z
When using the FTP to load software, you can load only one software module by
executing one command.
Operation Procedure
Step 1
Execute the command
FTP ipaddress
to log in to the BTS by using the following user name
and password:
z
User name: system
z
Initial password: system
Step 2
Execute the command
PUT
File.Path File.Name
to download the specified software to the
BTS.
To load file
bckm3606.bzp
stored in drive D, execute the command
PUT
D:\bckm3606.bzp.
Step 3
After the loading is successful, execute the command
LI ACT Boardname.Type
to activate
the specified software.
To activate the CPU software of the BCKM, execute the command
LI ACT
bckm.cpu.
You can obtain the help information by executing the command
LI ACT?.
z
The loading sequence is: CMTR/OMTR
→
CCPM/CECM
→
BCIM
→
BCKM.
z
For the loading of each board, you must load the FPGA before loading the CPU software.
z
To minimize the impact on service provision, you can load all the BTS software and then
activate the software in order when the traffic is low.
Step 4
Execute the command
DSP CBTSBRDVER
to check whether the activation is successful.
Step 5
If the activation is successful, repeat the steps 2 and 3 to activate all the BTS software.
----End