3 Commissioning Process
Airbridge BTS3606E&3606AE
System Commissioning Guide
3-12
Huawei Technologies Proprietary
Issue 02 (2006-10-10)
z
The BTS is configured with the QC54BCIM.
Operation Procedure
To configure the IP address and routing information of the BTS locally, do as follows:
Step 1
Log in to the BTS locally. See 3.3.2 "Locally Logging In to the BTS in Telnet
Mode
"
for
details.
Step 2
Set the IP address of the BCIM by executing the command
SET CBTSBCIMIP
.
Step 3
Set the IP address of the FE port of the BCIM by executing the command
ADD
CBTSFEPORT
.
Step 4
Set the routing information of the BTS by executing the command
ADD CBTSIPROUTE
.
Step 5
Set the IP address of the BTS O&M by executing the command
SET CBTSOAMIP
.
----End
3.3.4 Starting the LMT
This section describes how to start the LMT.
Task Description
Log in to the BAM through the LMT.
Prerequisites
Before starting the LMT, ensure that:
z
The BAM server is operational.
z
The LMT is installed with the O&M software.
z
The network connection between the LMT and the BAM is normal.
z
The user name, password, and related authorities of the WS have been defined in the
BAM.
Operation Procedure
To start the LMT, do as follows:
Step 1
Select
Start
>
All Programs
>
iManager M2000
>
LocalWS
.
The
Local NE Management System
dialog box is displayed.
Step 2
Click
Configure
to add the IP address of the BAM.
Step 3
Select the BAM to be logged in to and click
OK
.
The system starts the service maintenance system automatically and the
User Login
dialog
box is displayed.
Step 4
Type in the valid user name and password, as shown in Figure 3-7.