7
WFS 101545 Operations Manual
The spindle coolant loop is rated at 10 GPM at 45 PSI
c.
Internal recirculating Loop
This loop constantly recirculates process water returned from the lift station through filters
and cooling.
d.
Lift Station
The lift station returns contaminated water from the dicing process to the WFS.
SIMPLIFIED SCHEMATIC OF THE SPINDLE
CHILLER
SPINDLE COOLANT
CHAMBER
SPINDLE
MOTORS
WFS 101545
SIMPLIFIED SCHEMATIC OF THE
INTERNAL RECIRCULATING LOOP
DIRTY
CLEAN
FILTER
CHILLER
WEIR