12
WFS 101545 Operations Manual
Figure 4-2 shows the minimum door height clearance required to accommodate passage of
the main WFS platform prior to assembly.
c.
Electrical Power Requirements
WFS requires the following:
3 phase 40 amp circuit
230 VAC 50 hz or 220 VAC 60 hz
The Lift Station requires the following:
115 VAC 50/60 hz
7.5 Amps
See manufactures design data in appendix
d.
Leveling Base
Prior to assembly the base must be properly leveled and supported at six (6) points. Figure
4-3 shows the leveler location. A standard spirit or bubble level will provide sufficient
accuracy for leveling the unit.
FIGURE 4-2