Figure 40: Switch page—Fabric Parameters tab
4. Set the fabric parameters:
a.
At the
BB_Credit
field, type a value from 1 through 60 buffers. The
default is 16. Use a value of 60 buffers only for extended distance port
operation.
b.
At the
R_A_TOV field
, type a value from 10 through 1200 tenths of a
second (one through 120 seconds). The default is 10 seconds (100 tenths).
All fabric-attached switches must be set to the same R_A_TOV. If the
value is not compatible, the E_Port connection to the switch segments and
the switch cannot communicate with the fabric. In addition, the
R_A_TOV must be greater than the E_D_TOV.
c.
At the
E_D_TOV
field, type a value from 2 through 600 tenths of a
second (0.2 through 60 seconds). The default is 20 tenths of a second
(2 seconds).
All fabric-attached switches must be set to the same E_D_TOV. If the
value is not compatible, the E_Port connection to the switch segments and
the switch cannot communicate with the fabric. In addition, the
E_D_TOV must be less than the R_A_TOV.
d. The switch priority value designates the fabric’s principal switch. The
principal switch controls the allocation and distribution of domain IDs for
all fabric directors and switches (including itself). At the
Switch Priority
field, select
Principal
,
Never Principal
, or
Default
(the default setting is
Default
).
Summary of Contents for storageworks 2/32
Page 10: ...Contents 10 Edge Switch 2 32 Installation Guide ...
Page 18: ...About this Guide 18 Edge Switch 2 32 Installation Guide ...
Page 86: ...Installing and Configuring the Edge Switch 2 32 86 Edge Switch 2 32 Installation Guide ...
Page 112: ...Manage Firmware Versions 112 Edge Switch 2 32 Installation Guide ...
Page 119: ...Regulatory Compliance Notices 119 Edge Switch 2 32 Installation Guide Japanese Notice ...
Page 124: ...Regulatory Compliance Notices 124 Edge Switch 2 32 Installation Guide ...