Diagnostic and system error messages reference guide
96
Fabric OS 3.x Document Addendum
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-INTNIL
Message
Probable Cause
The ASIC failed to get a CMI error (interrupt). This usually indicates an ASIC failure. This
message is generated by the
cmitest
command. The
error code
value is for internal use
only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-INTNOTCLR
Message
<timestamp>
CRITICAL DIAG-INTNIL, 1, <test name>, pass <number>,
Pt<port information> Failed to get CMI Error (interrupt),
Err# <error code>
<timestamp>
CRITICAL DIAG-INTNOTCLR, 1, <test name>, pass <number>,
Pt<port information> Offs <offset value> CMEM_ERR int bit could not be
cleared,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...