Fabric OS reference guide
169
Fabric OS 3.x Document Addendum
Disable Nodename Zone Checking
By default, zoning uses both port WWN and node WWN to perform zoning. When the option
is set to
1
, node WWN cannot be used in zoning.
RSCN Transmission Mode
Table 16
provides the RSCN transmission mode values. Each field is described following the
table.
End-Device RSCN Transmission Mode
End-device RSCN transmission mode values are:
■
0
RSCN contains only a single PID.
■
1
RSCN contains multiple PIDs.
■
2
Fabric address RSCN.
Domain RSCN-to-End Device for Switch IP Address or Name Change
Domain RSCN to end-device for switch IP address or name change values are:
■
0
Disabled. No domain RSCN is sent to the end device for a switch IP address change or
a name change.
■
1
Enabled. Domain RSCN is sent to the end device for a switch IP address change or a
name change.
Arbitrated Loop Settings
Table 17
defines settings affecting Fibre Channel arbitrated loops that can be changed. Each
field is described after the table.
Table 15: Zoning Operation Parameter
Field
Type
Default
Range
Disable Nodename Zone Checking
Boolean
0
0 or 1
Table 16: RSCN Transmission Mode
Field
Type
Default
Range
End-Device RSCN Transmission Mode
Number
1
0 to 2
Domain RSCN-to-End Device for Switch IP
Address or Name Change
Number
0
0 to 1
Table 17: Arbitrated Loop Settings
Field
Type
Default
Range
Send FAN frames?
Boolean
1
0 or 1
Always send RSCN?
Boolean
0
0 or 1
Enable CLOSE on OPEN Received?
Number
4
0 to 4
Do Not Allow AL_PA 0x00?
Boolean
0
0 or 1
Initialize All Looplets?
Boolean
0
0 or 1
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...