Diagnostic and system error messages reference guide
108
Fabric OS 3.x Document Addendum
DIAG-STATS (FTX)
Message
Probable Cause
The port counter value did not match the number of frames actually transmitted. In this case,
FramesTx
equals the number of frames transmitted. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the
portloopbacktest
command. The
error code
value is
for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-TBRAM_DEC_RWTEST
Message
Probable Cause
The ASIC internal registers failed the read-modify-write operation. This usually indicates an
ASIC failure. This message is generated by the
turboramtest
command. The
error
code
value is for internal use only.
<timestamp>
CRITICAL DIAG-STATS (FTX), 1, <test name>, pass <number>,
Pt<port info> FramesTx Counter Wrong, is <actual value> sb <expected
value>,
Err# <error code>
<timestamp>
CRITICAL DIAG-TBRAM_DEC_RWTEST, 1, <test name>, pass <number>,
Pt<port info> Failed Turbo RAM dec r/w test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
rpt=0x<actual pattern> wpt=0x<expected pattern> msk=0x<mask value>
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...