Diagnostic and system error messages reference guide
80
Fabric OS 3.x Document Addendum
DIAG-BADINT
Message
Probable Cause
A port received an unexpected interrupt. This usually indicates an ASIC failure. This message
is generated by the
centralmemorytest
or the
cmitest
command. The
error code
value is for internal use only.
Recommended Action
For the HP StorageWorks SAN Switch 2/16, replace the motherboard FRU.
For the HP StorageWorks SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-BUS_TIMEOUT
Message
Probable Cause
The ASIC register or ASIC SRAM did not respond to an ASIC data access. This usually
indicates an ASIC failure. This message is generated by the
portregtest
or the
sramretentiontest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-BADINT, 1, <test name>, pass <number>,
Pt<port information> got interrupt,
int_status=0x<int number> when not expecting one,
Err# <error code>
<timestamp>
CRITICAL DIAG-BUS_TIMEOUT, 1, <test name>,
Pt<port information> BTO accessing <Register Name> Register at Address
<address>,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...