Diagnostic and system error messages reference guide
89
Fabric OS 3.x Document Addendum
DIAG-CMNOBUF
Message
Probable Cause
The port could not get any buffers. This usually indicates an ASIC failure. This message is
generated by the
centralmemorytest
command. The
error code
value is for internal
use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-DATA
Message
Probable Cause
The payload received by a port did not match the payload transmitted. This can be caused by a
faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard
or ASIC. This message is generated by the
crossporttest
or
portloopbacktest
command. The
error code
value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
<timestamp>
CRITICAL DIAG-CMNOBUF, 1, <test name>, pass <number>,
Pt<port information> No More Buffers,
Err# <error code>
<timestamp>
CRITICAL DIAG-DATA, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: RX Data is 0x<actual value>
sb 0x<expected value> er 0x%<err value>,
Err# <error code>
Summary of Contents for StorageWorks 2/16 - SAN Switch
Page 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Page 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Page 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Page 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Page 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Page 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...