Hardware options installation 36
10.
Connect the rest of the drive cables required in this drive configuration. For more information, see
"Storage cabling (on page
71
)."
11.
In the four-bay LFF drive cage configuration, HP recommends securing the excess length of the Mini-SAS
cable by using the cable clip that came with the kit:
a.
Use the two vertical dash marks in front of the fan cage to position the clip correctly, and then attach
the cable clip.
b.
Secure the excess length of the Mini-SAS cable in the cable clip.
12.
If you intend to use an FBWC module and capacitor pack, install these options now ("
Installing the
FBWC module and capacitor pack
" on page
39
).
13.
Install the access panel (on page
20
).
14.
Install the server into the rack ("
Installing the server into the rack
" on page
27
).
15.
Power up the server (on page
17
).
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
16.
Install the drives ("
Installing a hot-plug drive
" on page
32
).
Mini-SAS Y-cable option
The Mini-SAS Y-cable in this option kit supports HP Smart Array controller board options in the eight-bay SFF
drive configuration.
To connect the cable option:
1.
Power down the server (on page
17
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
17
).
o
Remove the server from the rack (on page
18
).
Summary of Contents for ProLiant DL360e Gen8
Page 6: ...Contents 6 ...
Page 16: ...Component identification 16 Fan locations ...
Page 78: ...Cabling 78 GPU power cabling ...
Page 106: ...Support and other resources 106 ...
Page 107: ...Support and other resources 107 ...