Hardware options installation 40
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
17
).
o
Remove the server from the rack (on page
18
).
4.
Remove the access panel (on page
19
).
5.
Remove the PCI riser cage (on page
20
).
CAUTION:
When connecting or disconnecting the capacitor pack cable, the connectors on the
cache module and cable are susceptible to damage. Avoid excessive force and use caution to
avoid damage to these connectors.
6.
Connect the capacitor pack cable to the cache module.
7.
If using the embedded array controller:
a.
Install the cache module on the system board.
b.
Install the PCI riser cage (on page
21
).
8.