Table 7-1
POST numeric codes and text messages (continued)
Control panel message
Description
Recommended action
103-System Board Failure
DMA or timers.
1.
Clear CMOS.
2.
Replace the system board.
162-System Options Not Set
Configuration incorrect.
RTC (real-time clock) battery might need to
be replaced.
Run Computer Setup and check the
configuration in Advanced > Onboard
Devices.
Reset the date and time under Control
Panel. If the problem persists, replace the
RTC battery.
163-Time & Date Not Set
Invalid time or date in configuration
memory.
RTC (real-time clock) battery may need to
be replaced.
Reset the date and time under Control Panel
(You can also use Computer Setup). If the
problem persists, replace the RTC battery.
See the Removal and Replacement section
for instructions on installing a new battery,
or contact an authorized dealer or reseller
for RTC battery replacement.
163-Time & Date Not Set
CMOS jumper might not be properly
installed.
Check for proper placement of the CMOS
jumper if applicable.
164-MemorySize Error
Memory amount has changed since the last
boot (memory added or removed).
Press the
f1
key to save the memory
changes.
164-MemorySize Error
Memory configuration incorrect.
1.
Run Computer Setup or Windows
utilities.
2.
Be sure the memory modules are
installed properly.
3.
If third-party memory has been
added, test using HP-only memory.
4.
Verify proper memory module type.
201-Memory Error
RAM failure.
1.
Be sure that memory modules are
correctly installed.
2.
Verify proper memory module type.
3.
Remove and replace the identified
faulty memory modules.
4.
If the error persists after replacing
memory modules, replace the system
board.
213-Incompatible Memory Module in
Memory Socket(s) X, X, ...
A memory module in memory socket
identified in the error message is missing
critical SPD information, or is incompatible
with the chipset.
1.
Verify proper memory module type.
2.
Try another memory socket.
3.
Replace DIMM with a module
conforming to the SPD standard.
214-DIMM Configuration Warning
Populated DIMM Configuration is not
optimized.
Rearrange the DIMMs so that each channel
has the same amount of memory.
92
Chapter 7 POST error messages
ENWW
Summary of Contents for ProDesk 400 G7 SFF
Page 8: ...Index 125 viii ENWW ...
Page 12: ...4 Chapter 1 Product features ENWW ...
Page 56: ...48 Chapter 4 Removal and replacement procedures ENWW ...
Page 82: ...74 Chapter 5 Troubleshooting without diagnostics ENWW ...
Page 106: ...98 Chapter 7 POST error messages ENWW ...
Page 128: ...120 Chapter 11 Statement of memory volatility ENWW ...
Page 132: ...124 Chapter 13 Specifications ENWW ...
Page 136: ...128 Index ENWW ...