SROS Command Line Interface Reference Guide
Global Configuration Mode Command Set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
530
thresholds [BES | CSS | DM | ES | LCV | LES | PCV | SEFS | SES | UAS]
[15Min | 24Hr]
<threshold count>
Use the
thresholds
command to specify DS1 performance counter thresholds. Use the
no
form of this
command to return to default settings.
Syntax Description
BES
Specifies the bursty errored seconds threshold.
CSS
Specifies the controlled slip seconds threshold.
DM
Specifies the degraded minutes threshold.
ES
Specifies the errored seconds threshold.
LCV
Specifies the line code violations threshold.
LES
Specifies the line errored seconds threshold.
PCV
Specifies the path coding violations threshold.
SEFS
Specifies the severely errored framing seconds threshold.
SES
Specifies the severely errored seconds threshold.
UAS
Specifies the unavailable seconds threshold.
15Min
Specifies that the threshold you are setting is for the counter’s 15 minute statistics.
24Hr
Specifies that the threshold you are setting is for the counter’s 24 hour statistics.
<threshold>
Specifies the maximum occurrences allowed for this error type. Once a threshold
is exceeded, an event is sent to the console specifying the appropriate counter.
Additionally, if SNMP traps are enabled, the unit will send a trap with the same
information as the console event.
Default Values
The default values for this command are as follows:
thresholds BES 15Min 10
thresholds BES 24Hr 100
thresholds CSS 15Min 1
thresholds CSS 24Hr 4
thresholds DM 15Min 1
thresholds DM 24Hr 4
thresholds ES 15Min 65
thresholds ES 24Hr 648
thresholds LCV 15Min 13340
thresholds LCV 24Hr 133400
thresholds LES 15Min 65
thresholds LES 24Hr 648
thresholds PCV 15Min 72
thresholds PCV 24Hr 691
thresholds SES 15Min 10
Note
Threshold settings are applied to ALL DS1s.