SROS Command Line Interface Reference Guide
G.703 Interface Configuration Command set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
679
coding [ami | hdb3]
Use the
coding
command to configure the line coding for the G.703 physical interface. This setting must
match the line coding supplied on the circuit by the PBX.
Syntax Description
ami
Configures the line coding for alternate mark inversion (AMI).
hdb3
Configures the line coding for high-density bipolar 3 (HDB3).
Default Values
By default, all E1 interfaces are configured with HDB3 line coding.
Functional Notes
The line coding configured in the unit must match the line coding of the E1 circuit. A mismatch will result in
line errors (e.g., BPVs).
Usage Examples
The following example configures the G.703 interface for AMI line coding:
ProCurve(config)#
interface e1 1/2
ProCurve(config-e1 1/2)#
coding ami