Effect
The cursor was closed but all rows affected by opening this cursor have been rolled
back.
Recovery
OPEN the cursor again and FETCH all rows until SQLCODE = 100 is returned.
SQL 8889
8889 The provided buffer to retrieve Result Set proxy syntax is either
null or not big enough.
Cause
An HP Neoview database call-level interface (CLI) function was unable to provide
proxy syntax for a stored procedure result set because the provided target buffer is either null
or not big enough.
Effect
The operation fails.
Recovery
Make the CLI call again and use a buffer big enough to hold the proxy syntax.
Consider using the len_of_item output parameter from the first CLI call to obtain the actual
size of the buffer needed to return the proxy syntax.
SQL 8890
8890 The SQL compiler failed to initialize properly. Query results may
differ from what is expected, due to different compiler defaults.
Cause
The HP Neoview database compiler failed to correctly initialize.
Effect
Query results might be affected.
Recovery
Stop the Neoview database software and restart it.
SQL 8891
8891 Non-ASCII character host variable type was specified for name
field.
name
is the name of the field.
Cause
The host variable type for the field
name
must be ASCII.
Effect
The operation fails.
Recovery
Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
SQL 8893
8893 The statement argument count does not match the descriptor entry
count.
Cause
You specified a statement whose argument count does not match the descriptor entry
count.
Effect
The operation fails.
Recovery
Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
SQL 8894
8894 Argument argument-name of CLI function function-name is reserved
for future use and must be set to string when calling the function.
Cause
A value that was passed into an HP Neoview database CLI function containing a
reserved parameter was not the value expected by the database software.
Effect
The CLI function fails.
Recovery
Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
218
Executor Messages (8000 Through 8999)
Summary of Contents for Neoview Messages
Page 12: ...12 ...
Page 66: ...66 ...
Page 129: ...Recovery Supply the input values for the IDENTITY column 129 ...
Page 130: ...130 ...
Page 172: ...172 ...
Page 178: ...178 ...
Page 184: ...184 ...
Page 238: ...238 ...
Page 266: ...266 ...
Page 268: ...268 ...
Page 350: ...350 ...
Page 378: ...378 ...
Page 384: ...384 ...
Page 400: ......