101
Configuring the agent
1.
Enable SNMP agent:
a.
Select
Device
>
SNMP
from the navigation tree.
The SNMP configuration page appears.
b.
Select the
Enable
option, and select the
v3
option.
c.
Click
Apply
.
Figure 105 Configuring the SNMP agent
2.
Configure an SNMP view:
a.
Click the
View
tab.
b.
Click
Add
.
The page for creating an SNMP view appears.
c.
Type
view1
in the
View Name
field.
d.
Click
Apply
.
Figure 106 Creating an SNMP view (1)
e.
On the page that appears, select the
Included
option, type the MIB subtree OID
interfaces
,
and click
Add
.
f.
Click
Apply
.
A configuration progress dialog box appears.
g.
Click
Close
after the configuration process is complete.