227
RX loss of signal(channel 4)
RX power low(channel 1)
RX power low(channel 2)
RX power low(channel 3)
RX power low(channel 4)
Table 38 Command output
Field Description
transceiver current alarm information
Alarms present on the transceiver module.
RX loss of signal
Received signals are lost.
RX power low
Received power is low.
display transceiver diagnosis
Use
display transceiver diagnosis
to display the current values of the digital diagnosis parameters
on transceiver modules.
Syntax
display transceiver diagnosis interface
[
interface-type interface-number
]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
interface
[
interface-type interface-number
]: Specifies an interface by its type and number. If no
interface is specified, this command displays the current values of the digital diagnosis parameters
on every transceiver module.
Usage guidelines
This
command cannot display information about some transceiver modules.
Examples
# Display the current values of the digital diagnosis parameters on the transceiver module in
interface FortyGigE 1/0/1.
<Sysname> display transceiver diagnosis interface fortygige 1/0/1
FortyGigE1/0/1 transceiver diagnostic information:
Current diagnostic parameters:
[module] Temp.(°C) Voltage(V)
33 3.29
[channel] Bias(mA) RX power(dBm) TX power(dBm)
1 7.96 -1.03 -0.64
2 7.69 -0.83 -0.56
3 7.79 -0.42 -0.59
4 8.08 -0.55 -0.47