6-4
Error Messages
Error Messages in Alphabetical Order
ARGUMENT OUT OF RANGE
Error Number
206
The argument for a programming command is out of the specified range. Refer
to the programmer’s guide for a list of programming commands and argument
ranges.
ASCII: MISSING 'BEGIN' STATEMENT
Error Number
193
The CITIfile you just downloaded over the HP-IB or via disk was not properly
organized. The analyzer is unable to read the "BEGIN" statement.
ASCII: MISSING 'CITIFILE' STATEMENT
Error Number
194
The CITIfile you just downloaded over the HP-IB or via disk was not properly
organized. The analyzer is unable to read the "CITIFILE" statement.
ASCII: MISSING 'DATA' STATEMENT
Error Number
195
The CITIfile you just downloaded over the HP-IB or via disk was not properly
organized. The analyzer is unable to read the "DATA" statement.
ASCII: MISSING 'VAR' STATEMENT
Error Number
196
The CITIfile you just downloaded over the HP-IB or via disk was not properly
organized. The analyzer is unable to read the "VAR" statement.
AVERAGING INVALID ON NON-RATIO MEASURE
Error Number
13
You cannot use sweep-to-sweep averaging in single-input measurements.
Sweep-to-sweep averaging is valid only for ratioed measurements (A/R, B/R,
A/B, and S-parameters). You can use noise reduction techniques, such as
narrower IF bandwidth, for single input measurements.
BAD FREQ FOR HARMONIC OR FREQ OFFSET
Error Number
181
You turned on time domain or recalled a calibration that resulted in start and
stop frequencies that are beyond the allowable limits.
BATTERY FAILED. STATE MEMORY CLEARED
Error Number
183
The battery protection of the non-volatile CMOS memory has failed. The CMOS
memory has been cleared. Refer to the service guide for battery replacement
instructions. See
Chapter 8 , “Preset State and Memory Allocation”
information about the CMOS memory.
Summary of Contents for 8719ES
Page 6: ...vi ...
Page 10: ...Contents x Contents ...
Page 11: ...1 1 1 HP 8719 20 22ES Specifications and Characteristics ...
Page 60: ...1 50 HP 8719 20 22ES Specifications and Characteristics Instrument Specifications ...
Page 61: ...2 1 2 HP 8719 20 22ET Specifications and Characteristics ...
Page 98: ...2 38 HP 8719 20 22ET Specifications and Characteristics Instrument Specifications ...
Page 99: ...3 1 3 Front Rear Panel ...
Page 111: ...4 1 4 Menu Maps ...
Page 113: ...4 3 Menu Maps Menu Maps Figure 4 2 Menu Map for Copy ...
Page 114: ...4 4 Menu Maps Menu Maps Figure 4 3 Menu Map for Display ...
Page 115: ...4 5 Menu Maps Menu Maps Figure 4 4 Menu Map for Format Figure 4 5 Menu Map for Local ...
Page 116: ...4 6 Menu Maps Menu Maps Figure 4 6 Menu Map for Marker Marker Fctn and Marker Search ...
Page 118: ...4 8 Menu Maps Menu Maps Figure 4 9 Menu Map for Power and Sweep Setup ET only ...
Page 119: ...4 9 Menu Maps Menu Maps Figure 4 10 Menu Map for Power and Sweep Setup ES only ...
Page 120: ...4 10 Menu Maps Menu Maps Figure 4 11 Menu Map for Preset ...
Page 121: ...4 11 Menu Maps Menu Maps Figure 4 12 Menu Map for Save Recall ...
Page 122: ...4 12 Menu Maps Menu Maps Figure 4 13 Menu Map for Scale Ref ...
Page 128: ...5 1 5 Hardkey Softkey Reference ...
Page 194: ...6 1 6 Error Messages ...
Page 222: ...7 1 7 Options and Accessories ...
Page 234: ...8 1 8 Preset State and Memory Allocation ...
Page 253: ...8 20 Preset State and Memory Allocation Memory Allocation ...
Page 254: ...9 1 9 Understanding the CITIfile Data Format ...
Page 269: ...9 16 Understanding the CITIfile Data Format Useful Calculations ...
Page 270: ...10 1 10 Determining System Measurement Uncertainties ...
Page 281: ...10 12 Determining System Measurement Uncertainties Measurement Uncertainty Equations ...