5-46
Hardkey/Softkey Reference
Analyzer Functions
recalls the previously saved modified version of the color
set. This key appears only when a color set has been
saved.
provides access to the recall keys menu where specific
registers can be recalled.
presents the recall keys menu as the initial menu when
has been pressed.
recalls the instrument state saved in register 1.
recalls the instrument state saved in register 2.
recalls the instrument state saved in register 3.
recalls the instrument state saved in register 4.
recalls the instrument state saved in register 5.
recalls the instrument state saved in register 6.
recalls the instrument state saved in register 7.
is used in conjunction with sequencing, to return the
instrument to the known preset state without turning off
the sequencing function. This is not the same as pressing
the
key: no preset tests are run, and the HP-IB
and sequencing activities are not changed.
provides access to the Receiver Cal Menu.
selects the display reference line for color modification.
selects the reference line for printer color modification.
sets the position of the reference line on the graticule of a
Cartesian display, with 0 the bottom line of the graticule
and 10 the top line. It has no effect on a polar or Smith
display. The reference position is indicated with a small
triangle just outside the graticule, on the left side for
channel 1 and the right side for channel 2.
changes the value of the reference line, moving the
measurement trace correspondingly. In polar and Smith
chart formats, the reference value is the same as the scale,
and is the value of the outer circle.
defines the measurement as S
11
, the complex reflection
coefficient (magnitude and phase) of the test device input.
defines the measurement as S
22
, the complex reflection
coefficient (magnitude and phase) of the test device
output.
RECALL COLORS
RECALL KEYS MENU
RECALL KEYS on OFF
Save/Recall
RECALL REG1
RECALL REG2
RECALL REG3
RECALL REG4
RECALL REG5
RECALL REG6
RECALL REG7
RECALL STATE
Preset
RECEIVER CAL
REF LINE
REF LINE [ ]
REFERENCE POSITION
REFERENCE VALUE
REFL: FWD S11 (A/R)
REFL: REV S22 (B/R)
Summary of Contents for 8719ES
Page 6: ...vi ...
Page 10: ...Contents x Contents ...
Page 11: ...1 1 1 HP 8719 20 22ES Specifications and Characteristics ...
Page 60: ...1 50 HP 8719 20 22ES Specifications and Characteristics Instrument Specifications ...
Page 61: ...2 1 2 HP 8719 20 22ET Specifications and Characteristics ...
Page 98: ...2 38 HP 8719 20 22ET Specifications and Characteristics Instrument Specifications ...
Page 99: ...3 1 3 Front Rear Panel ...
Page 111: ...4 1 4 Menu Maps ...
Page 113: ...4 3 Menu Maps Menu Maps Figure 4 2 Menu Map for Copy ...
Page 114: ...4 4 Menu Maps Menu Maps Figure 4 3 Menu Map for Display ...
Page 115: ...4 5 Menu Maps Menu Maps Figure 4 4 Menu Map for Format Figure 4 5 Menu Map for Local ...
Page 116: ...4 6 Menu Maps Menu Maps Figure 4 6 Menu Map for Marker Marker Fctn and Marker Search ...
Page 118: ...4 8 Menu Maps Menu Maps Figure 4 9 Menu Map for Power and Sweep Setup ET only ...
Page 119: ...4 9 Menu Maps Menu Maps Figure 4 10 Menu Map for Power and Sweep Setup ES only ...
Page 120: ...4 10 Menu Maps Menu Maps Figure 4 11 Menu Map for Preset ...
Page 121: ...4 11 Menu Maps Menu Maps Figure 4 12 Menu Map for Save Recall ...
Page 122: ...4 12 Menu Maps Menu Maps Figure 4 13 Menu Map for Scale Ref ...
Page 128: ...5 1 5 Hardkey Softkey Reference ...
Page 194: ...6 1 6 Error Messages ...
Page 222: ...7 1 7 Options and Accessories ...
Page 234: ...8 1 8 Preset State and Memory Allocation ...
Page 253: ...8 20 Preset State and Memory Allocation Memory Allocation ...
Page 254: ...9 1 9 Understanding the CITIfile Data Format ...
Page 269: ...9 16 Understanding the CITIfile Data Format Useful Calculations ...
Page 270: ...10 1 10 Determining System Measurement Uncertainties ...
Page 281: ...10 12 Determining System Measurement Uncertainties Measurement Uncertainty Equations ...