![HP 8719ES Reference Manual Download Page 178](http://html.mh-extra.com/html/hp/8719es/8719es_reference-manual_161529178.webp)
5-51
Hardkey/Softkey Reference
Analyzer Functions
makes scale per division the active function. A menu is
displayed that is used to modify the vertical axis scale and
the reference line value and position. In addition this
menu provides electrical delay offset capabilities for
adding or subtracting linear phase to maintain phase
linearity.
searches the trace for the next occurrence of the target
value to the left.
searches the trace for the next occurrence of the target
value to the right.
moves the active marker to the maximum point on the
trace.
moves the active marker to the minimum point on the
trace.
turns off the marker search function.
searches for the user-specified target point on the trace.
specifies which limit segment in the table is to be modified.
A maximum of three sets of segment values are displayed
at one time, and the list can be scrolled up or down to show
other segment entries. Use the entry block controls to
move the pointer > to the required segment number. The
indicated segment can then be edited or deleted. If the
table of limits is designated "EMPTY," new segments can
be added using the
or
softkey.
sets the center frequency of a subsweep in a list frequency
sweep.
enters the IF bandwidth for the active segment in a swept
list table. This key is disabled if
is
set to OFF.
enters absolute power values in the swept list table. The
power values are restricted to the current power range
setting.
If port power is uncoupled, power applies to the currently
selected port, otherwise it applies to both ports. (The list
table only displays one port's power values at time due to
limited display area.) To set the alternate port's power
level, you must exit the edit list menus, select a
measurement that activates the alternate port, and then
re-enter the edit list menus.
This key is disabled if
is set to
.
Scale Ref
SEARCH LEFT
SEARCH RIGHT
SEARCH: MAX
SEARCH: MIN
SEARCH: OFF
SEARCH: TARGET
SEGMENT
ADD
EDIT
SEGMENT: CENTER
SEGMENT IF BW
LIST IF BW on OFF
SEGMENT POWER
LIST POWER
OFF
Summary of Contents for 8719ES
Page 6: ...vi ...
Page 10: ...Contents x Contents ...
Page 11: ...1 1 1 HP 8719 20 22ES Specifications and Characteristics ...
Page 60: ...1 50 HP 8719 20 22ES Specifications and Characteristics Instrument Specifications ...
Page 61: ...2 1 2 HP 8719 20 22ET Specifications and Characteristics ...
Page 98: ...2 38 HP 8719 20 22ET Specifications and Characteristics Instrument Specifications ...
Page 99: ...3 1 3 Front Rear Panel ...
Page 111: ...4 1 4 Menu Maps ...
Page 113: ...4 3 Menu Maps Menu Maps Figure 4 2 Menu Map for Copy ...
Page 114: ...4 4 Menu Maps Menu Maps Figure 4 3 Menu Map for Display ...
Page 115: ...4 5 Menu Maps Menu Maps Figure 4 4 Menu Map for Format Figure 4 5 Menu Map for Local ...
Page 116: ...4 6 Menu Maps Menu Maps Figure 4 6 Menu Map for Marker Marker Fctn and Marker Search ...
Page 118: ...4 8 Menu Maps Menu Maps Figure 4 9 Menu Map for Power and Sweep Setup ET only ...
Page 119: ...4 9 Menu Maps Menu Maps Figure 4 10 Menu Map for Power and Sweep Setup ES only ...
Page 120: ...4 10 Menu Maps Menu Maps Figure 4 11 Menu Map for Preset ...
Page 121: ...4 11 Menu Maps Menu Maps Figure 4 12 Menu Map for Save Recall ...
Page 122: ...4 12 Menu Maps Menu Maps Figure 4 13 Menu Map for Scale Ref ...
Page 128: ...5 1 5 Hardkey Softkey Reference ...
Page 194: ...6 1 6 Error Messages ...
Page 222: ...7 1 7 Options and Accessories ...
Page 234: ...8 1 8 Preset State and Memory Allocation ...
Page 253: ...8 20 Preset State and Memory Allocation Memory Allocation ...
Page 254: ...9 1 9 Understanding the CITIfile Data Format ...
Page 269: ...9 16 Understanding the CITIfile Data Format Useful Calculations ...
Page 270: ...10 1 10 Determining System Measurement Uncertainties ...
Page 281: ...10 12 Determining System Measurement Uncertainties Measurement Uncertainty Equations ...