S
YSTEM
P
ARAMETERIZATION AND
O
PERATION
80 / 157
System 6844(RC) - V03.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
The time can be increased by pressing the
+
key and reduced with the
-
key.
When quitting the program by pressing
BR
the last displayed value is stored in fail-safe
manner.
When
IRIG-B.(1) TimeOFF = 255
minutes, the IRIG time code is always
transmitted as soon as a valid time is available in the System.
5.5.5.4 IRIG-B.(2) Configuration/TimeOFF (Option)
In System 6844(RC), there is an option to enable a second digital IRIG-B output.
The following menu items only appear when the IRIG-B.(2) signal is ena-
bled.
Selection frame:
I R I G - B . ( 2 )
C O N F . B Y T E
Y / N
and
Selection frame:
I R I G - B . ( 2 )
T i m e O F F
Y / N
Configuration takes place in the same way as for the IRIG-B.(1) signal.
5.5.6 Activate LAN Management Board (Board 6844RC only)
In order that the LAN Management Board / Module of Control Board 6844RC can be config-
ured and monitored, the LAN Management Board / Module must be activated in the 6844RC
menu.
Selection frame:
L A N M A N A G E M E N T
B O A R D A C T I V . Y / N
Input frame:
L A N _ M N G > D E A C T I V .
+ / -
or
Input frame:
L A N _ M N G > A C T I V .
+ / -
The LAN Management Board / Module is activated or deactivated in the 6844RC with the
+
and
-
key (ACTIVATION/DEACTIVATION).
An activated LAN Management Board / Module will be monitored for its presence. If an error
is detected here, this will be indicated in the ERROR byte.