6.3.6 T-String
Below the T-String is described.
The T-string can be transmitted in all modes (e.g.
forerun
or
last control characters on the
second change
). The data string can be requested by
"T"
.
6.3.6.1 Specified Settings
Automatic:
no
Required:
no
Blocked:
no
6.3.6.2 Structure
Character No.
Meaning
Hex-Value
1
"T" ASCII T
$54
2
":" colon
$3A
3
tens year
$30-39
4
unit year
$30-39
5
":" colon
$3A
6
tens month
$30-31
7
unit month
$30-39
8
":" colon
$3A
9
tens day
$30-33
10
unit day
$30-39
11
":" colon
$3A
12
tens day of the week
$30
13
unit day of the week
$31-37
14
":" colon
$3A
15
tens hour
$30-32
16
unit hour
$30-39
17
":" colon
$3A
18
tens minute
$30-35
19
unit minute
$30-39
20
":" colon
$3A
21
tens second
$30-36
22
unit second
$30-39
23
CR (carriage return)
$0D
24
LF (line feed)
$0A
6.3.6.3 Status
No status contained in the T-String.
6.3.6.4 Example
T:02:07:18:04:12:34:56(CR)(LF)
It is Thursday 18.07.02 - 12:34:56 o'clock