Pulse configuration
Selection frame:
S E T P U L S E
O U T P U T Y / N
Input frame:
P U L S E 7 6 5 4 3 2 1 0
B Y T E >
0 0 0 0 0 0 0 1
Reference value for 1U
In the second line, the individual bits can now be set to
"0"
or
"1"
, whereby
"1"
is to be seen
as a start-up function.
The meanings of the individual bits are as follows:
B7
Pulse Level Direction
0
Not inverted (
low active)
1
Inverted (
high active)
If all bits in Mode 1, 2 and 3 are set to "0" (zero), Modes are disabled
there is no output on the pulse output.
After disabling the Modes, it is recommended to trigger a program re-
set.
Only one Mode can be enabled.
Enabling of several Modes is prohibited. In the event of a prohibited
configuration there is no output on the pulse output.
If a function is set in the corresponding Mode, the bits of the other
Modes must be set to "0" (zero).
The meaning of the individual bits of the Mode configuration:
B6
B5
Mode 3: DCF77
0
0
Mode 3 disabled
0
1
DCF77 pulse (time base: UTC)
1
0
Not assigned (currently DCF77 pulse (time base: UTC))
1
1
Not assigned (currently DCF77 pulse (time base: UTC))
B4
B3
B2
B1
Mode 2: Cyclical Pulse Output
0
0
0
0
Mode
2 disabled
0
0
0
1
Second pulse, duration = 250msec
0
0
1
0
Minute pulse, duration = 1000msec
0
0
1
1
Not assigned (currently second pulse, duration = 250msec)
0
1
0
0
Hour pulse, duration = 1sec
0
1
0
1
Not assigned (currently second pulse, duration = 250msec)
0
1
1
0
Not assigned (currently second pulse, duration = 250msec)
0
1
1
1
Not assigned (currently second pulse, duration = 250msec)
1
0
0
0
Day pulse (local time 00:00:00), duration = 1000msec
1
0
0
1
Day pulse (local time 12:00:00), duration = 1000msec
1
0
1
0
Not assigned (currently second pulse, duration = 250msec)
1
0
1
1
Not assigned (currently second pulse, duration = 250msec)
1
1
0
0
Not assigned (currently second pulse, duration = 250msec)
1
1
0
1
Not assigned (currently second pulse, duration = 250msec)
1
1
1
0
Not assigned (currently second pulse, duration = 250msec)
1
1
1
1
Not assigned (currently second pulse, duration = 250msec)
B0
Mode 1: System Time Status Output
0
Mode 1 disabled
1
Output System synchronization status (radio mode)