6.3.9.3 Status
The characters 28-31 in the data string SINEC H1 Extended tell the synchronisation status of
the clock.
The characters mean the following:
character no. 28 = "#"
no radio synchronisation after reset, time invalid
" " (space) radio synchronisation after reset, clock in crystal operation
character no. 29 = "*"
time from internal crystal in the clock
" " (space) time by radio reception
character no. 30 = "S"
daylight saving time
"U"
UTC
(see chapter
Mode Byte 1 / Bit7 - Local Time or UTC in the Serial Output
" " (space) standard time
character no. 31 = "!"
announcement of a DST or standard time changeover
"A"
announcement of a leap second
" " (space) no announcement
6.3.9.4 Example
(STX)D:18.07.02;T:4;U:12.34.56; _ _ _ _ (ETX)
( _ ) = Space
It is Thursday 18.07.02 - 12:34:56 o'clock
radio operation
standard time (winter time)
no announcement of a changeover