5.2.7 Serial Interface Parameters
The interface parameters and the output mode can be entered separately for each of the two
serial interfaces. The following selection frames will be displayed (for configuration see
Chapter 6 COM0 / COM1 Serial Interfaces
Using the COM0 interface as Remote-Interface (RC Systems) and COM1
interface as synchronisation interface (Sub-Master Systems) the interfaces
are not available for any other functions.
5.2.7.1 Selection Frames for Parameters of Serial Interface COM0
Setting serial Parameter
Selection frame:
S E T C O M 0 S E R I A L
P A R A M E T E R Y / N
The parameters for
B
aud rate,
W
ord length,
P
arity bit and
S
top bit must be entered in se-
quence in the following input frame:
Input frame:
B d :
0 9 6 0 0
W :
8
P :
N
S :
1
_
Setting Mode Byte 1
Selection frame:
S E T C O M 0
M O D E B Y T E _ 1 Y / N
Input frame:
M o d B _ 1 7 6 5 4 3 2 1 0
C O M 0 >
1 1 0 0 1 1 0 0
Setting Mode Byte 2
Selection frame:
S E T C O M 0
M O D E B Y T E _ 2 Y / N
Input frame:
M o d B _ 1 7 6 5 4 3 2 1 0
C O M 0 >
1 1 1 0 1 1 0 0
Depending on the selected string,
Mode Byte 3
is also available in the
menu for the required configuration of the string.
Setting Mode Byte 3
Selection frame:
S E T C O M 0
M O D E B Y T E _ 3 Y / N
Input frame:
M o d B _ 3 7 6 5 4 3 2 1 0
C O M 0 >
0 0 0 0 0 0 0 1