196
Thor VM2 with with Microsoft Windows Embedded CE 6.0 User Guide
the Code ID. If Strip Code ID is enabled, the data should not include the Code ID since
it has already been stripped.
Add Prefix/Suffix Control
Start > Settings > Control Panel > Data Collection tab > Symbology button
Use this option to specify a string of text, hex values or hat encoded values to be added
to the beginning (prefix) or the end (suffix) of the bar code data.
Up to 19 characters can be included in the string. The string can include any character
from the keyboard plus characters specified by hex equivalent or entering in hat encod-
ing. See
for a list of characters with their hex and hat-encoded values.
Use the Escape function to enter literal hex and hat values.
Note:
Non-ASCII equivalent keys in Key Message mode are unavailable in this option. Non-ASCII
equivalent keys include the function keys (e.g. F1), arrow keys, Page up, Page down, Home,
and End.
Symbologies
The Thor VM2 supports only Custom IDs.
Ctrl Char Mapping
The Ctrl Char Mapping button (Control Character Mapping) activates a dialog to define
the operations the Data Collection Wedge performs on control characters (values less
than 0x20) embedded in bar codes.
Add
Prefix
To enable a prefix, check the Prefix checkbox and enter the desired string in the text box.
The default is disabled (unchecked) with a blank text string. When bar code data is processed,
the Prefix string is sent to the output buffer before any other data.
Because all stripping operations have already occurred, stripping settings do not affect the
prefix. The prefix is added to the output buffer for the Symbology selected from the pull-down
list.
If ‘All’ is selected, the prefix is added for any symbology that has not been specifically
configured.
Add
Suffix
To enable a suffix, check the Suffix checkbox and enter the desired string in the text box.
The default is disabled (unchecked) with a blank text string. When bar code data is processed,
the Suffix string is sent to the output buffer after the bar code data.
Because all stripping operations have already occurred, stripping settings do not affect the
suffix. The suffix is added to the output buffer for the Symbology selected from the pull-down
list.
If ‘All’ is selected, the suffix is added for any symbology that has not been specifically
configured.
Summary of Contents for Thor VM2
Page 1: ...User Guide Thor VM2 Vehicle Mounted Computer with Microsoft Windows Embedded CE 6 0 ...
Page 16: ...4 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 63: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 51 ...
Page 64: ...52 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 288: ...276 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 310: ...298 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 352: ...340 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 385: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 373 Hat Encoding ...
Page 398: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VM2 CE UG Rev D 9 17 ...