70 Technical Data
Honeywell
10
10. TECHNICAL DATA
10.1 SMARTDRIVE COMPACT TECHNICAL DATA
Mains
connection
Input voltage U
in
380 - 480V, -15%...+10% 3~
208…240V, -15%...+10% 1~
Input frequency
45…66 Hz
Line current THD
> 120%
Connection to mains
Once per minute or less (normal case)
Supply
network
SmartDrive Compact cannot be used with corner
grounded networks
Motor
connection
Output voltage
0 - U
in
Output current
Continuous rated current I
N
at ambient tempera-
ture max. +50ºC, overload 1.5 x I
N
max. 1min/
10min
Starting current /
torque
Current 2 x I
N
for 2 secs in every 20 sec period.
Torque depends on motor
Output frequency
0…320 Hz
Frequency resolution 0,01 Hz
Control
characteristics
Control method
Frequency Control U/f
Open Loop Sensorless Vector Control
Switching frequency
1...16 kHz; Factory default 6 kHz
Frequency reference
Resolution 0.01 Hz
Field weakening
point
30…320 Hz
Acceleration time
0.1…3000 sec
Deceleration time
0.1…3000 sec
Braking torque
100%*T
N
with brake option (only in 400V > 1,5
kW) 30%*T
N
without brake option
Table 10.1 : SmartDrive Compact technical data