Washer
LockWasher
Nut
Bolt
Foot Rest
Hinge
Fig. 9
Fig. 8
Fig. 10
Rotary
Plunger
Pin
Foldable Foot Rests
Foldable foot rests provide workers with a rest platform
within the system and conveniently fold out of the way
when not in use.
1. Shift the hinge over the back of the guide rail and align
the holes in the foot rest hinge with the oblong hole in
the rail.
2. Fix it on by inserting bolt through the aligned holes and
attach washer, lockwasher and nut. Torque fastener to
18.5 ft.-lbs. (25Nm).
Shaft Entering device with Coupling
1. Install coupling to the top of the uppermost guide rail
section by aligning the holes in the coupling with the
holes in the guide rail and inserting the bolts (see Fig.
9). Attach lockwashers and nuts. Torque fasteners to
18.5 ft.-lbs. (25Nm).
2. Insert shaft entering device vertically into the coupling
as shown.
Rotary Exit
A rotary exit may be installed at the top of the system to
assist users with entering and exiting the system safely.
To use the rotary exit, first make sure the fall arrester is lo-
cated completely in the upper rotary exit rail section. Then
simply pull the rotary plunger pin (located at the back of
the rotary exit) downward to release the locking mecha-
nism and rotate the upper rotary exit rail section 180° until
it locks into place.
1. Install the rotary exit to the top guide rail section by
aligning the holes in the rotary exit with the holes in the
guide rail and inserting the bolts. Attach flatwashers,
lockwashers and nuts. Torque fasteners to 18.5 ft.-lbs.
(25Nm).
NOTE: The rotary exit together with the top guide rail
section must not extend more than 36 in. (914mm) past
the top ladder rung. When installing the top guide rail
section, reduce the rail projection by 7 in. (178mm) to
allow for the rotary exit.
WARNING:
The top end stop must always be
present when using the rotary exit and/or ladder
system.