10. Connect the pyrolyzer to the detector with
the three provided mounting screws (see
Diagram 9-6).
Diagram 9-6. Attaching the pyrolyzer.
terminal
module
power switch
rectangular access at
bottom of bracket
mounting
screws (3)
pyrolyzer
socket
(con5)
connector
tubes
WARNING
To maintain sensor accuracy
when using the pyrolyzer, perform a gas calibration
every six months. Do not allow the ambient tem-
perature at the point of installation to exceed 40°C
(104°F). Operation above this temperature may require
more frequent bump testing or calibration to confirm
working specification. Because of the higher operat-
ing temperatures when using the pyrolyzer module,
Honeywell Analytics strongly recommends that the
ventilated Midas Top Cover (shown in Diagram 9-1) be
used in all pyrolyzer applications.
Note:
Consult the label on the side of the Pyrolyzer
module, as shown in Diagram 9-7, for the
firmware version level required in the Midas
detector for proper operation.
Diagram 9-7. Pyrolyzer label.
P/N: MIDAS-T-NP1
05/16 REV 1 S/N:00001
For non-flammable gases only
www.honeywellanalytics.com
This pyrolyzer is to be used only
with Midas extractive units
equipped with version 1.10 or later
application software
.
Summary of Contents for Midas
Page 7: ...Midas Gas Detector 1 1 1 Description ...
Page 9: ...Midas Gas Detector 2 1 2 Overview ...
Page 14: ...Midas Gas Detector 3 1 3 Default Configuration ...
Page 17: ...Midas Gas Detector 4 1 4 Installation ...
Page 41: ...Midas Gas Detector 5 1 5 Startup ...
Page 43: ...Midas Gas Detector 6 1 6 Operation ...
Page 53: ...Midas Gas Detector 7 1 7 Navigating Modes and Submenus ...
Page 74: ...Midas Gas Detector 8 1 8 Maintenance ...
Page 82: ...Midas Gas Detector 9 1 9 Pyrolyzer Module Options ...
Page 89: ...Midas Gas Detector 10 1 10 Optional LonWorks Interface Installation ...
Page 99: ...Midas Gas Detector 11 1 11 Troubleshooting and Fault Diagnosis ...
Page 102: ...Midas Gas Detector 12 1 12 REFLEX ...
Page 104: ...Midas Gas Detector 13 1 13 Internal Web Server ...
Page 106: ...Midas Gas Detector 13 3 Diagram 13 1 IPAddress setting in Windows XP ...
Page 129: ...Midas Gas Detector 14 1 14 Typical Installation Topologies ...
Page 132: ...Midas Gas Detector 15 1 15 Ordering Information ...
Page 136: ...Midas Gas Detector 16 1 16 Specifications ...
Page 139: ...Midas Gas Detector 17 1 17 Calibration and Bump Testing ...
Page 143: ...Midas Gas Detector A 1 A Modbus TCP Interface ...
Page 150: ...Midas Gas Detector B 1 B Gas Tables ...
Page 158: ...Midas Gas Detector C 1 C Warranty ...