OPERATING INSTRUCTIONS
1
3
4
It is the latest handheld gas leak detector. It features
the following functions :
1. Flexible probe
2. Sensor cap
3. Indicator LED
4. ON/OFF key
5. Earphone jack
(Dia.:3.5 mm)
6. Adaptor jack
(Dia.: outer:4mm/inner:1.3mm)
7. Mute slide switch
Sensor: Semiconductor
Response time: < 10 seconds
Warm up time: < 60 seconds
o
o
Operation temp. Range: -5 C ~45 C
Power off : 10 minutes from power on
Power supply : 4pcs AA batteries (alkaline one
suggested) or 9V adaptor.
Battery life: 14 hours (Continuous working)
Minimum BAT. voltage: 4.8V
Probe length:
Size: 175 x 70 x 38 mm (HxWxT)
Indicator: Intermittent beep(Acoustic) / LED (Visual)
447 mm
1. Methane 5 level LED
2. Propane 5 level LED
3. Sensor ready LED
4. Power on & Bat. OK LED
5. Bat. Low LED
MEASUREMENT OPERATION
1. Power ON/OFF
Press ON/OFF key more than 0.2 second to turn on
the meter. While the meter is on and electrical power
is enough, the BAT. OK LED will stay on.
To ensure the accuracy, users must perform the
warm-up in the clean air.
The meter will be automatically switched off in 10
minutes. Or you could press ON/OFF key again to
turn off.
!
Please note that the left methane value on 7201
doesn't equal to the right side propane value.
So, make sure the gas you measure then read
the value from the correct side.
2. Warm-up status
While the meter is power on but Ready LED doesn’t
light on, the sensor warm-up is in process. It takes
around 60 seconds and Ready LED is on when it
is ready to measure.
GAS LEAK DETECTOR
2
INTRODUCTION
INDICATOR
1
2
3
4
5
6
7
Detects methane and propane gas.
Quick to pinpoint gas leaks.
Automatically calibrate when power is on.
Auto power off to save battery life.
60 seconds warm up time.
Response time less than 10 seconds.
5-level LED leak alarm.
Over 440mm long flexible probe.
Built in earphone jack.
Mute function.
During this phase, a special compensating circuit
automatically allows to limit the effect of environ-
mental change.
Even you turn off the meter for a short time and
turn on again, it is always needed to wait for
60 seconds warm-up time.
MODEL: 7201
MODEL: 7291
General Specification
Specification Difference Table
Methane
Propane
Fast response & High
Methane sensitivity
120 to 1920 ppm
40 to 640 ppm
40ppm (
Propane
)
120ppm (
Methane
)
7201
7291
Range
40 to 640 ppm
Sensitivity
40ppm
(
Propane & Methane
)
Advantage
Filter included for
high discrimination
1
2
3
4
5
(Example:7201)
SPECIFICATIONS