User’s Manual ver. 2.0
CD3200 up to110A
Honeywell
7
www.honeywell.com/imc
2.2 Input features
Input signal
Input
Impedance
Analog 0÷10V
8200 ohm
Analog 4÷20mA
100 ohm
Potentiometer
10Kohm
8200 ohm
2.3 Output features
NA=not Available
Current
Voltage range
Ripetitive peak
reverse voltage
Latching
current
Max peak
one cycle
Leakage
current
I
2
T value for
fusing
Frequency
range
Power
loss
Isolation
Voltage
(A) (V)
(440V)
(500V)
(mAeff)
(10msec.)
(A)
(mAeff)
tp=10msec (Hz) I=Inom
(W)
Vac
15A 24÷440 1200 NA 150
230
15
610 47÷70 18 2500
25A 24÷440 1200 NA 150
230
15
610 47÷70 30 2500
35A
24÷500 1200 1600 250
400
15
780 47÷70 42 2500
45A
24÷500 1200 1600 250
600
15
1800 47÷70 54 2500
60A
24÷500 1200 1600 450
1000
15
4750 47÷70 72 2500
90A
24÷500 1200 1600 450
2000
15
19200 47÷70 108 2500
110A 24÷500 1200 1600 450
1350
15
8830 47÷70 137 2500
2.4 Derating curve
1
0.8
0.6
0.4
0.2
0
45
55
65
75
85
K
°C
I = I x K
NOM
MAX