![Homa H832-15/0,37W Original Instruction Manual Download Page 41](http://html1.mh-extra.com/html/homa/h832-15-0-37w/h832-15-0-37w_original-instruction-manual_2147767041.webp)
41
If the HPS 2 is used, the following faults may occur in addition to those above:
HPS 2 does not switch the pump on, or switches off automatically after a short time
Cause
Remedy
Control electronics defective
Send HPS 2 in and have it checked by works after-sales
service
Membrane in the HPS 2 defective
Have HPS 2 checked by works after-sales service
Pump runs but is not switched off by the HPS 2
Cause
Remedy
Leakage in the pressure line, the loss of water is
more than 0.6 l/min
Seal leakage in the pressure line
"Reset" button on the HPS 2 is defective
Have HPS 2 checked by works after-sales service
The upper flow meter located in the HPS 2 is
defective
Have HPS 2 checked by works after-sales service
Control electronics defective
Have HPS 2 checked by works after-sales service
HPS 2 switches the pump on and off without water being drawn off
Cause
Remedy
Leakage in the pressure line, the loss of water is
more than 0.6 l/min
Leckage in der Druckleitung abdichten
Control electronics defective
Have HPS 2 checked by works after-sales service
Further steps for troubleshooting
If the aforementioned points do not help you to eliminate the fault, contact our customer service. They can help
you as follows:
Assistance by telephone or in writing by the customer service
Support on site by the customer service
Check/repair of the machinery in the factory
Please note that the use of certain services of our customer service might incur further costs! Please contact our
customer service for further information.