3.3.1. Type plate
1 Ph
3 Ph
3.3.2. Motor
The motor consists of an engine block and the engine shaft with the impeller assembly. The circuit for power
supply is designed for the maximal mechanical performance according to the characteristics or the nameplate of
the pump. The cable inlets as well as the circuit are sealed resistant to jet water towards the pumped medium.
The shaft bearing is carried out by means of robust, maintenance-free and permanently lubricated antifriction
bearings.
General motor nameplate data
Operating mode with submersed motor
S3 40%
Permitted medium temperature
35°C
Insulation class
B (130°C)
Protection class
IP68
Cable length
30 m
Voltage Model W
230V / 50Hz / 1Ph
Voltage Model D
400V / 400V / 3Ph
3.3.3. Monitoring devices
Temperature sensor
The pump type is equipped with a temperature sensor set in the motor windings, which switches the motor off in
the event of overheating of the winding.
After cooling, the motor will restart automatically.
The triggering temperature of the sensors for standard version motors is 130°C.
Checking direction of rotation
No check is required for single-handed motors, since these always run in the correct direction.
Three phase motors have the correct direction of rotation if connected to a clockwise rotating field (U, V, W -> L1,
L2, L3). HOMA switchgears check the circuit for a clockwise rotating field. If there is no clockwise rotating field,
the red LED flashes. Two phases have to be interchanged at the input of the switchgear. For smaller pumps, the
check can be carried out by observation of the start-jerk.
No.
1 Ph
3 Ph
1
Type description
Type description
2
Serial number
Serial number
3
Impeller diameter
Impeller diameter
4
Temperature of medium
Temperature of medium
5
Immersion depth
Immersion depth
6
Weight
Weight
7
Hmax (delivery head max)
Hmax (delivery head max)
8
Hmin (delivery head min)
Hmin (delivery head min)
9
Qmax (delivery volume max)
Qmax (delivery volume max)
10
Standard
Standard
11
Construction
product
regulations-test lab
Construction product regulations-
test lab
12a
Year type test
Year type test
12b
Declaration of performance
Declaration of performance
13
Build year
Build year
14
Motor type
Motor type
15
IE Marking
IE-Marking
16
Frequency
Frequency
17
Voltage
Voltage
– 3-phase
18
Nominal current
Nominal current 3-phase
19
Motor RPM
Motor RPM
20
Power P1
Voltage
– Star connection
21
Cos phi
Nominal current Star connection
22
Insulation class
Insulation class
23
Power P2
Power P1
24
Start condenser
Cos phi
25
Operating condenser
Protection class
26
Protection class
Power P2
27
Operating class
Operating class
28
Text field sales
Text field sales