9.12 MARKERS
Markers
provide the user with useful amplitude information at specific frequencies. There are two
sets of Markers available, Decade Markers and User Markers. Decade Markers are set at fixed
frequencies and User Markers are customizable.
NOTE:
If Smoothing is applied to a trace, the Markers will appear on an average value.
Dynamic Marker:
Holding the 'CTRL' button with your mouse cursor in the plot area will enable a
Dynamic Marker. The Dynamic Marker will follow the x-axis position of the mouse and move along
the selected trace, while displaying frequency and amplitude.
9.12.1 DECADE MARKERS
Decade Markers
are a set of 7 fixed markers. They display amplitude at every decade from
10Hz offset to 10MHz offset.