138
7-5
4
R
B
4
A
2
1
T
7-6
User Code
* = Factory confi guration
(
Fig
.
7-6
)
Storing the selected mode of operation
in the permanent memory
If an operating mode is to be transferred into the
permanent memory, fi rst modify its status, e.g.: activate
or deactivate it and then transfer it into the permanent
memory. (not possible for the Compensation function
of the residual imbalances).
To store the selection permanently:
—
“
SETTINGS
”(
4
)
—
“
General Confi gurations
” (
A
)
—
“
Save the operating mode on the
permanent memory
” (
1
),
—
Touch the fi eld (
2
) and select;
-
No
(*) =
No storage (
2
).
-
Activate
=
Data are stored in the permanent
memory (
2
).
A three-tone signal sounds to confi rm acceptance.
Main shaft stop position
(
T
,
Fig. 7-5
)
The positioning brake stops the main shaft close to the
correction position by initiating pulsing braking.
The positioning brake is activated after switch on and
after a measuring run has been carried out and found
an unbalance greater than the limit value.
Select:
•
“
SETTINGS
”(
4
)
•
“
Operational confi guration
” (
B
)
•
“
Stop position and indexing
” (
T
)
—
Touch the fi eld (
R
).
•
Choose one of the following options (
R
):
-
No
= No positioning brake after measuring run.
-
Left side
(*)= Positioning brake after measuring run
for left plane.
-
Right side
= Positioning brake after measuring run
for right plane.
Note
: The selection can be acquired in the
permanent memory.
..
..
..
.
..
. .
..
.