6 System integration
Operating manual mzr-2521 and mzr-2921
Last update: June 2019
Technical data subject to change without prior notice!
43
Startup of the micro annular gear pump with the S-BL control unit
speed regulation
serial interface of PC
external voltage supply
24 V DC / 2.5 A
Status LED
S
D
mzr-pump
+
-
switch S1
figure 29
Connection of the micro annular gear pump mzr-2521 or mzr-2921 and the S-BL control unit
1.
Connect the motor cable to the 6-pole connector of the S-BL control unit.
The pin configuration is indicated in table 14 and table 25.
Function
Connection
Color
Phase A
Ph A
brown
Phase B
Ph B
orange
Phase C
Ph C
yellow
Hall sensor A
Hall A
green
Hall sensor B
Hall B
blue
Hall sensor C
Hall C
grey
V5 V
Vcc
red
Ground
SGND
black
table 25
Pin configuration of the motor
2.
Connect the RS-232 port of the MCBL3006 with a free serial interface of a
PC. For this purpose use the delivered 9-pole null-modem cable.
3.
Put the potentiometer of the S-BL control unit to zero position by turning it
clockwise to the limit stop.
4.
Connect the voltage supply 24 VDC. This can be done with the integrated
DIN connector or, alternatively the 2-pole screw clamp (24 V = »+«;
GND = »-«). Pay attention to the correct polarity.
5.
You may now install the delivered software »Motion Manager« as described
in the chapter 9.
While connecting the DC voltage pay attention to the correct polarity,
otherwise electronics may be damaged.