1 General information
Operating manual mzr-2521 and mzr-2921
Last update: June 2019
Technical data subject to change without prior notice!
5
1.5
Technical data of the micro annular gear pump mzr-2521 and mzr-2921
mzr-2521
mzr-2921
Technical data
Displacement volume
1.5 µl
3 µl
Housing length without fluid connections
69 mm
69 mm
Housing length with fluid connections
−
slip fitting version Ø 2 mm
−
manifold assembly version
75 mm
71 mm
75 mm
71 mm
Diameter
13 mm
13 mm
Weight
−
slip fitting version Ø 2 mm
−
manifold assembly version
56 g
65 g
56 g
65 g
Internal volume
65 µl
67 µl
Housing material
stainless steel
316L (1.4404),
epoxy resin adhesive
stainless steel
316L (1.4404),
epoxy resin adhesive
Fluid connector material
stainless steel 316L (1.4404)
Rotor material
tungsten carbide (WC-Ni)
Bearing material
tungsten carbide (WC-Ni) / ceramics
Dynamic sealing
graphite-reinforced PTFE, stainless steel spring 316L
Static sealing
FKM; optional EPDM, FFKM
Performance parameters
Min. flow rate Q (at 1 rpm)
0.0015 ml/min*
0.003 ml/min*
Max. flow rate Q (at 6000 rpm)
9 ml/min (= 0.54 l/h)
18 ml/min (= 1.08 l/h)
Min. dosage volume
0.25 µl
0.5 µl
Differential pressure (at viscosity 1 mPas)
1.5 bar
3 bar
Max. applied inlet pressure
1 bar
1 bar
Viscosity
0.3 --- 100 mPas
(1000 mPas*)
0.3 --- 100 mPas
(1000 mPas*)
Dosage precision CV
1 %
1 %
Operating temperature
-20 … 60 °C
-20 … 60 °C
Ambient temperature
-20 … 65 °C
-20 … 65 °C
Storage temperature
10 … 40 °C
10 … 40 °C
Pulsation of flow (theoretical value)
1.5 %
6 %
NPSHR value
0.6 m
0,6 m
Legend:
* with supplementary modules
CV Coefficient of variation
NPSHR Net Positive Suction Head Required
table 1
Technical data and performance parameters of the micro annular gear pumps mzr-2521 and mzr-2921
Warning
The material property of a liquid (e.g. viscosity, lubricating property, particle
content, corrosiveness) impacts the technical data and the service life of
pumps.
At appropriate conditions the characteristic values may be increased or
decreased.
Warning
If you intend to operate the pump out of the range of the above given
specification, please consult the manufacturer. Modifications may be necessary
to ensure successful operation. Otherwise the pump or the system may be
damaged seriously.