OEM MANUAL:K6602924
2 PRODUCT SPECIFICATION OUTLINE
Revision: 1 / Date: 2003.03.06
Page:
27
/ 273
2.3.3 VERIFY ERROR RETRY
The controller performs the same retry as the read error retry mentioned in
section 2.3.1
READ ERROR RETRY for the verify error during the verify
operation.
The host computer can change the error management of the controller with the
verify error recovery parameter (Page Code 7H) of the MODE SELECT command.
2.3.4 SEEK ERROR RETRY
The controller performs the same retry as the read error retry or write error retry
mentioned in section 2.3.1 READ ERROR RETRY and 2.3.2 WRITE ERROR
RETRY for seek error during the seek action.
2.3.5 SPINDLE ERROR RETRY
The controller retries the spin up operation 4 times when a start spindle error
occurs during execution of the Start Unit command or the Auto Start operation.
The controller also retries the spin up operation once when an unexpected spin
down error occurs during execution of the medium access command.
2.3.6 ERROR RETRY CONTROL
The host computer can change the number of retries of the controller with the
error recovery parameter of MODE SELECT command.
The error recovery parameter may be specified to the controller by each host
computer independently.
The summary of error control is explained below.
Refer to the description of 5.5 MODE SELECT command.
(1) Default Mode
The controller specifies the processing given below as Default Mode.
·Executing the following number of retries until error is recovered.
Read Error
128 retries
Write Error
128 retries