OEM MANUAL:K6602924
5 COMMAND DESCRIPTIONS
Revision: 1 / Date: 2003.03.06
Page: 79 / 273
No data is transferred if the Allocation Length is set to 0. This condition, however,
is not considered as an error. Other allocation length values specify the maximum
number of bytes to be transferred. The controller terminates the Data In phase
when the number of bytes specified in the Allocation Length field have been
transferred or when all available inquiry data have been transferred to the host
computer, whichever is less.
The controller reports the CHECK CONDITION status only when it cannot transfer
the requested inquiry data. The controller does not report the CHECK
CONDITION status for the INQUIRY command even if the UNIT ATTENTION
status is held pending.
And the Unit Attention status is not cleared by INQUIRY command.
The Standard Inquiry Data is shown in Table 5.8 and the Vital Product Data are
shown in Table 5.10 (Supported Vital Product Data) and Table 5.11 (Unit Serial
Number).
Table 5.8 Standard Inquiry Data
Bit
Byte
7
6
5
4
3
2
1
0
0
Peripheral Qualifier
Peripheral Device Type
1
RMB
Device Type Modifier
0
0
0
0
0
0
0
0
2
ISO Version
ECMA Version
ANSI Version
0
0
0
0
0
0
1
1
3
AENC
Trm IOP
Reserved
Response Data Format
0
0
0
0
0
0
1
0
4
Additional Length (6B
H
)
0
1
1
0
1
0
1
1
5
Reserved
0
0
0
0
0
0
0
0
6
Reserved
Addr16
0
0
0
0
0
0
0
7
RelAdr WBus32 Wbus16 SYNC Linked TranDis
CmdQue
SftRe
0
0
1
1
1
1
0
8-15
Vendor Identification (in ASCII)
“HITACHI€”
16-31
Product Identification (in ASCII)
32-35
Product Revision Level (in ASCII)
(cont
’
d)
INQUIRY:(12h)