![Hitachi Ultrastar 15K73 Reference Manual Download Page 270](http://html.mh-extra.com/html/hitachi/ultrastar-15k73/ultrastar-15k73_reference-manual_146694270.webp)
OEM MANUAL:K6602594
6 SENSE DATA
Revision: 1 / Date: 2003.03.06
Page: 270 / 273
6
5B 01
Threshold
Condition Met
The Log condition has met threshold
condition.
1
5B 02
Log Counter at
Maximum
The Log counter have reached to the
maximum value.
1
5B 03
Log List Codes
Exhausted
The Log List codes were exhausted.
0 or 1
or 6
5D 00
Failure Prediction
Threshold Exceeded
The informational exception conditions
occured.
0 or 1
or 6
5D FF
Failure Prediction
Threshold Exceeded
(False)
The false informational exception conditions
occured.
1
80 00
Read with Pin Hit
Data is read, but this data has Pin.
4
94 00
Auto-Reallocation
Fail at No REC
Sector
Auto-Reallocation failed at no REC sector.
1
AE 00
Spare Sector Less
Than Threshold
Spare sector for relocation is less than
threshold, and relocate operation will be
unable to be executed.
4
E0 00
ETF Failed
A ETF completed in the abnormal condition