OEM MANUAL:K6602924
5 COMMAND DESCRIPTIONS
Revision: 1 / Date: 2003.03.06
Page: 109 / 273
The general usage parameter is savable by initiator via the LOG SELECT
Command.
If the parameter is not yet set, the default value placed in the parameter field shall
be all zero data.
If the parameter control field(byte2) is not satisfied in Table 5.32, the CHECK
CONDITION Status with the ILLEGAL REQUEST Sense key is reported.
Self-Test Results Page (Page Code = 10
H
)
The Self-Test Results log page provides the results from the twenty most recent
self-tests.
Results from the most recent self-test or the self-test currently in progress shall be
reported in the first self-test log parameter; results from the second most recent
self-test shall be reported in the second self-test log parameter; etc. If fewer than
twenty self-tests have occurred, the unused self-test log parameter entries shall be
zero filled.
Table 5.33 Self-Test Results Page(Page Code = 10
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code
0
0
0
1
0
0
0
0
1
Reserved
0
0
0
0
0
0
0
0
2
(MSB)
Page Length (190
H
)
3
(LSB)
Self-Test Results Log Parameters
4
•
First Self-Test Results Log Parameters
•
23
|
|
384
•
Twentieth Self-Test Results Log Parameters
•
403
LOG SELECT:(4Ch)