OEM MANUAL:K6602594
6 SENSE DATA
Revision: 1 / Date: 2003.03.06
Page: 257 / 273
Table 6.2 Sense Keys (cont’d)
4
H
HARDWARE ERROR
:
Indicates that the controller has detected an
unrecoverable hardware error(e.g., controller failure,
device failure, parity error, etc.) during the execution of a
command or self-test.
5
H
ILLEGAL REQUEST
:
Indicates that illegal data has been found in the command
descriptor block or an additional parameter which is
specified as data for some commands (e.g., FORMAT
UNIT, MODE SELECT, etc.).
When the controller detects an invalid parameter in the
CDB, it terminates the command without updating the
medium. When an invalid parameter is found in an
additional parameter that is given as data, however, the
medium may have been already updated.
6
H
UNIT ATTENTION
:
Indicates that a Unit Attention condition (see 3.1.4) has
been created by a change in a Mode Select Parameter or
the controller being reset.
7
H
DATA PROTECT
:
Indicates that the controller has received a WRITE
command when the medium is protected against write
operations. The controller carried out no write operation.
8
H
BLANK CHECK
.
(Not used.)
9
H
Vendor Unique
.
(Not used.)
A
H
COPY ABORTED
(Not used.)
B
H
ABORTED COMMAND
:
Indicates that the controller has aborted the command.
The host computer can recover from this condition by
issuing the command again.
C
H
EQUAL
.
(Not used.)
D
H
VOLUME OVERFLOW
(Not used.)
E
H
MISCOMPARE
:
Indicates that a data compare of the byte compare
verification was unsuccessful.
F
H
Reserved