APPENDIX PARAMETER OBJECT LISTS
27
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com-
mand
Jump Frequency 1 (Param107)
1
163
4
0.00 to 400.00(Hz)
100
Get/Set
A063
Jump Freq Width 1 (Param108)
1
164
2
0.00 to 10.00(Hz)
100
Get/Set
A064
Jump Frequency 2 (Param109)
1
165
4
0.00 to 400.00(Hz)
100
Get/Set
A065
Jump Freq Width 2 (Param110)
1
166
2
0.00 to 10.00(Hz)
100
Get/Set
A066
Jump Frequency 3 (Param111)
1
167
4
0.00 to 400.00(Hz)
100
Get/Set
A067
Jump Freq Width 3 (Param112)
1
168
2
0.00 to 10.00(Hz)
100
Get/Set
A068
Accel Stop Freq (Param113)
1
169
4
0.00 to 400.00(Hz)
100
Get/Set
A069
Accel Stop Time (Param114)
1
170
2
0.0 to 60.0(s)
10
Get/Set
A070
PID Enable (Param115)
1
171
1
00(Invalid)/01(Valid)
1
Get/Set
A071
PID-P Gain (Param116)
1
172
1
0.2 to 5
1
Get/Set
A072
PID-I Gain (Param117)
1
173
2
0.0 to 3600.0(s)
10
Get/Set
A073
PID-D Gain (Param118)
1
174
2
0.00 to 100.00(s)
100
Get/Set
A074
PID Scale (Param119)
1
175
2
0.01 to 99.99(%)
100
Get/Set
A075
PID Feedback Sel (Param120)
1
176
1
00(OI)/01(O)
1
Get/Set
A076
AVR Selection (Param121)
1
181
1
00(ON)/01(OFF)/
02(OFF on decel)
1
Get/Set
A081
MotorVoltage Sel (Param122)
1
182
1
00(200)/01(215)/02(220)/03(230)/
04(240)/05(380)/06(400)/07(415)/
08(440)/09(460)/10(480)/11(575)/
12(600)
1
Get/Set
A082
OperationModeSel (Param123)
1
185
1
00(Normal)/01(Energy saving)/
02(Fuzzy)
1
Get/Set
A085
EnergySavingResp (Param124)
1
186
2
0.0 to 100.0(s)
10
Get/Set
A086
Accel Time 2 (Param125)
1
192
4
0.01 to 3600.00(s)
100
Get/Set
A092
2nd Accel Time 2 (Param344)
2
192
4
0.01 to 3600.00(s)
100
Get/Set
A292
3rd Accel Time 2 (Param378)
3
192
4
0.01 to 3600.00(s)
100
Get/Set
A392
Decel Time 2 (Param126)
1
193
4
0.01 to 3600.00(s)
100
Get/Set
A093
2nd Decel Time 2 (Param345)
2
193
4
0.01 to 3600.00(s)
100
Get/Set
A293
3rd Decel Time 2 (Param379)
3
193
4
0.01 to 3600.00(s)
100
Get/Set
A393
Accel/Decel2 Sel (Param127)
1
194
1
00(Terminal)/01(Frequency)
1
Get/Set
A094
2nd Acc/Dec2 Sel (Param346)
2
194
1
00(Terminal)/01(Frequency)
1
Get/Set
A294
Accel2 StartFreq (Param128)
1
195
4
0.00 to 400.00(Hz)
100
Get/Set
A095
2ndAcc2StartFreq (Param347)
2
195
4
0.00 to 400.00(Hz)
100
Get/Set
A295
Decel2 StartFreq (Param129)
1
196
4
0.00 to 400.00(Hz)
100
Get/Set
A096
2ndDec2StartFreq (Param348)
2
196
4
0.00 to 400.00(Hz)
100
Get/Set
A296
AccelPattern Sel (Param130)
1
197
1
00(Straight line)/01(S Curve)/
02(U Curve)/03(Reverse U Curve)
1
Get/Set
A097
DecelPattern Sel (Param131)
1
198
1
00(Straight line)/01(S Curve)/
02(U Curve)/03(Reverse U Curve)
1
Get/Set
A098
Support service
Service name
Code
Get_Attribute_Single
H’0E
Set_Attribute_Single
H’10
(2) Extend Group A object Class ID=102
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com-
mand
OI StartFreq Set (Param132)
1
101
4
0.00 to 400.00(Hz)
100
Get/Set
A101
OI End Freq Set (Param133)
1
102
4
0.00 to 400.00(Hz)
100
Get/Set
A102
OI Start Rate (Param134)
1
103
1
0 to 100(%)
1
Get/Set
A103
OI End Rate (Param135)
1
104
1
0 to 100(%)
1
Get/Set
A104
OI StartMode Sel (Param136)
1
105
1
00(Set Frequency)/01(0Hz)
1
Get/Set
A105
O2 StartFreq Set (Param137)
1
111
4
-400.00 to 400.00(Hz)
100
Get/Set
A111
O2 End Freq Set (Param138)
1
112
4
-400.00 to 400.00(Hz)
100
Get/Set
A112
O2 Start Rate (Param139)
1
113
1
-100 to 100(%)
1
Get/Set
A113
O2 End Rate (Param140)
1
114
1
-100 to 100(%)
1
Get/Set
A114
AccCurveSwelling (Param141)
1
131
1
01(small swelling) to
10(large swelling)
1
Get/Set
A131
DecCurveSwelling (Param142)
1
132
1
01(small swelling) to
10(large swelling)
1
Get/Set
A132
Support service
Service name
Code
Get_Attribute_Single
H’0E
Set_Attribute_Single