APPENDIX PARAMETER OBJECT LISTS
39
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com-
mand
OI StartMode Sel (Param136)
1
105
1
00(Set Frequency)/01(0Hz)
1
Get/Set
A105
O2 StartFreq Set (Param137)
1
111
4
-400.00 to 400.00(Hz)
100
Get/Set
A111
O2 End Freq Set (Param138)
1
112
4
-400.00 to 400.00(Hz)
100
Get/Set
A112
O2 Start Rate (Param139)
1
113
1
-100 to “O2 End Rate” (%)
1
Get/Set
A113
O2 End Rate (Param140)
1
114
1
“O2 Start Rate” to 100(%)
1
Get/Set
A114
AccCurveSwelling (Param141)
1
131
1
01(small swelling) to
10(large swelling)
1
Get/Set
A131
DecCurveSwelling (Param142)
1
132
1
01(small swelling) to
10(large swelling)
1
Get/Set
A132
Operation-target frequency
selection 1 (Param400)
1
141
1
00(Digital Operator)/
01(Keypad Potentiometer)/
02(Input via O)/
03(Input via OI)/
04(External Communication)/
05(Option1)/06(Option 2)/
07(Pulse-String Frequency input)
1
Get/Set
A141
Operation-target frequency
selection 2 (Param401)
1
142
1
00(Digital Operator)/
01(Keypad Potentiometer)/
02(Input via O)/
03(Input via OI)/
04(External Communication)/
05(Option 1)/06(Option 2)/
07(Pulse-String Frequency Input)
1
Get/Set
A142
Operator selection (Param402)
1
143
1
00(Addition
:
A141+A142)/
01(Subtraction
:
A141-A142)/
02(Multiplication
:
A141
×
A142)
1
Get/Set
A143
Frequency to be added
(Param403)
1
145
4
0.00 to 400.00(Hz)
1
Get/Set
A145
Sign of the frequency to be
added (Param404)
1
146
1
00(Forward)/01(Reverse)
1
Get/Set
A146
EL-S curve
acceleration/deceleration ratio 1
(Param405)
1
150
1
0 to 50(%)
1
Get/Set
A150
EL-S curve
acceleration/deceleration ratio 2
(Param406)
1
151
1
0 to 50(%)
1
Get/Set
A151
EL-S curve
deceleration/deceleration ratio 1
(Param407)
1
152
1
0 to 50(%)
1
Get/Set
A152
EL-S curve
deceleration/deceleration ratio 2
(Param408)
1
153
1
0 to 50(%)
1
Get/Set
A153
Support service
Service name
Code
Get_Attribute_Single
H’0E
Set_Attribute_Single
H’10
(3) Extend Group B object Class ID=103
Function
Inst
Attr
Size
Monitoring/Setting Range
Magnifi-
cation
Access
rule
Com
mand
Restart Mode Sel (Param143)
1
101
1
00(Trip)/01(0Hz Start)/
02(Synchronize)/
03(Sync& Stop& Trip)/
04(Restarting with active Matching
Frequency)
1
Get/Set
b001
Allowable UVTime (Param144)
1
102
1
0.3 to 25.0(s)
10
Get/Set
b002
Restart WaitTime (Param145)
1
103
2
0.3 to 100.0(s)
10
Get/Set
b003
IP/UVTrip AtStop (Param146)
1
104
1
00(Invalid)/01(Valid)/
02(Invalid on stop)
1
Get/Set
b004
IP/UVRestartTime(Param147)
1
105
1
00(16 times)/01(Free)
1
Get/Set
b005
Open-phaseSelect (Param148)
1
106
1
00(Invalid)/01(Valid)
1
Get/Set
b006
FreqSet To Match (Param149)
1
107
4
0.00 to 400.00(Hz)
100
Get/Set
b007