3-4
=====
Board Replacement Confirmation
=====
Is the replaced board EZJ104?
Solution When right, press [OK].
Cancel
OK
(6) It is displayed, "Wait for a minute", and progresses the indicator bar.
When the specific data stored on EZJ104 board are different from the data stored
on the EZJ93 board, following message screen “Board Replacement Procedure” is
displayed.
Select “EZJ104” on the message. (When the specific data stored on EZJ104
board and on EZJ93 board are same, this message is not displayed.)
(7) After pressing the replaced board button, following confirmation message will be
displayed. Check the message and press the button. After pressing the “Board
Replacement Confirmation“ button, the indicator bar progresses again.
The initialization of the board ends with step (6) and (7).
(8) When the initialization of the board ends, the print description screen is
displayed.
(9) Press the ejector (button) and take the system data memory card out of the slot.
(10) Execute “System reset” on the second page of the service maintenance screen.
(11) Input the serial number in the “Unit information” screen.
(12) Recover the data from the back up memory card by using the copy data function.
(From the memory card to the IJP)
(13) As the operation management, the parts usage time management, password
setup and the unit information are not backed up by the copy data function.
Set them again.
(Note. 1) The print data are the print description, the printing specifications, the print line, the print
format, the print condition and the count condition.
(Note. 2) The unit specific data are the ink type, the nozzle diameter and the viscosity calibration data.
As for the copy data function, the user mode and the service personnel
maintenance mode are different. When replacing the EZJ104, it is necessary to
back up the unit-specific data, and so put it into the service personnel
maintenance mode and then perform the backup.
-User mode: User data (printing data (Note 1), substitution rules, user patterns)
-Service personnel maintenance mode:
User data (same as above) and unit-specific data (Note 2).
Caution
As for the Unit
information, see “2.10
Unit information”.
As for the System
reset, see “2.8 System
reset”.
As for the copy data
function, see “2.9
Backup”.
=====
Board Replacement Procedure
=====
The EZJ104 board or the EZJ93 board replacement is
Solution Select the replaced board after checking having
EZJ93
EZJ104
detected.
backed up by the service personnel maintenance mode.
Summary of Contents for PXR
Page 1: ...Service Manual HITACHI Printer Model PXR Revision December 2008 Version C ...
Page 80: ...3 17 3 17 Circuit diagram of EZJ95 ...
Page 215: ...8 2 8 1 2 Circulation system diagram PXR P ...
Page 216: ...8 2 Air system diagram PXR P 8 3 ...
Page 217: ...8 4 8 3 Electrical Connection Diagram 8 3 1 Electrical Connection Diagram PXR D ...
Page 218: ...8 5 8 3 2 Electrical Connection Diagram PXR H ...
Page 219: ...8 3 3 Electrical connection diagram PXR P 8 6 ...