7-41
7.4.12 Excitation V-ref. Review
7.4.13 High Air Pressure
Excitation V-ref.
Review
Resume the
operation.
Readjust the excitation setup.
High Air Pressure
Continue operation.
Confirm pressure scale of filter
regulator.
Is it within adjustment
range? (0.10 – 0.11MPa)
Shut off pressure supply.
Can alarm be reset?
YES
NO
Adjust pressure.
YES
NO
Replace pressure switch.