4-12
5 Remove the fixing screws (2 positions) of the solenoid valve.
"Caution": Put wiping paper under the solenoid valve to provide for an ink
drip.
6 Clean the portion stained with ink and then install a solenoid valve by
reversing the above procedure.
"Caution" Set the O-ring in the groove of the solenoid valve securely.
Take care not to cause the O-ring to fall off or bite.
7 Reset the time of the corresponding solenoid to 0 on the “Parts usage time
management” screen.
Fixing screw
Solenoid valve
O-ring S16
O-ring 4.7
O-ring mounting groove
Incre-
ment
Decre-
ment
Cancel
changes
Reset
Back
0
9
8
7
6
5
4
3
2
1
Status: XXXXXXXXXXX
2005.07.07 12:45
Parts usage time
Ink filter
[ 0 0 0 0 0 ]
Circulation f.
[ 0 0 0 0 0 ]
Makeup ink f. [ 0 0 0 0 0 ]
Air filter
[ 0 0 0 0 0 ]
Pump
[ 0 0 0 0 0 ]
Recovery filter [ 0 0 0 0 0 ]
Heating unit
[ 0 0 0 0 0 ]
MV1
[
0
0 0 0 0 ]
(hours)
MV2
[ 0 0 0 0 0 ]
MV3
[ 0 0 0 0 0 ]
MV4
[ 0 0 0 0 0 ]
MV5
[ 0 0 0 0 0 ]
MV6
[ 0 0 0 0 0 ]
MV7
[ 0 0 0 0 0 ]
MV8
[ 0 0 0 0 0 ]
MV9
[ 0 0 0 0 0 ]
(hours)
Update log
2005.07.07 12:45
<Consumption>
I
nk [ 0 0 0 0 0 0 ] (ml)
Makeup ink [ 0 0 0 0 0 0 ] (ml)
Print count 0 0 0 0 0 0 0 0 0
Summary of Contents for PXR
Page 1: ...Service Manual HITACHI Printer Model PXR Revision December 2008 Version C ...
Page 80: ...3 17 3 17 Circuit diagram of EZJ95 ...
Page 215: ...8 2 8 1 2 Circulation system diagram PXR P ...
Page 216: ...8 2 Air system diagram PXR P 8 3 ...
Page 217: ...8 4 8 3 Electrical Connection Diagram 8 3 1 Electrical Connection Diagram PXR D ...
Page 218: ...8 5 8 3 2 Electrical Connection Diagram PXR H ...
Page 219: ...8 3 3 Electrical connection diagram PXR P 8 6 ...